Water Pump Ke Liye Kaunsa Wire Size Use Kare? (Full Guide)
Introduction
Ghar me water pump lagate waqt sabse bada doubt hota hai —
kaunsa wire lagaye taaki motor jale bhi nahi aur MCB trip bhi na kare
Zyada log motor ke HP pe dhyaan dete hain, lekin asli cheez hoti hai current (Ampere).
Galat wire size lagane se:
-
Motor heat hoti hai
-
Voltage drop hota hai
-
Overload trip hota hai
-
Winding jal sakti hai
Isliye pump ke hisaab se correct wire select karna bahut zaroori hai.
Pump ka Current kaise nikaale?
Formula:
Ampere = (HP × 746) ÷ Voltage
Single phase me approx formula use kar sakte ho:
1 HP ≈ 4 to 5 Ampere
Different HP Pump ke liye Wire Size Chart
| Pump Power | Current | Wire Size |
|---|---|---|
| 0.5 HP | 2–3A | 1.0 sqmm |
| 1 HP | 4–5A | 1.5 sqmm |
| 1.5 HP | 6–8A | 2.5 sqmm |
| 2 HP | 9–11A | 4 sqmm |
| 3 HP | 13–15A | 6 sqmm |
👉 Ye copper wire ke liye hai
Distance ka bhi effect hota hai
Agar motor door hai (20 meter se zyada) to wire mota lena padega.
Example:
-
1 HP pump normally → 1.5 sqmm
-
Door lagaya → 2.5 sqmm lena padega
Isko bolte hain voltage drop problem
Galat Wire Size se kya problem hoti hai?
1. Motor garam hona
Patla wire current rokta hai → motor heat
2. MCB trip hona
Starting current zyada hota hai → breaker trip
3. Winding jalna
Low voltage = high current = winding damage
Kaunsa MCB use kare?
General rule:
| |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|